Skip to content

Commit 8a21c19

Browse files
fix(logger): handle case-insensitive and integer log levels (#8836)
* fix(logger): handle case-insensitive and integer log levels Lowercase log levels crashed with TypeError when AWS_LAMBDA_LOG_LEVEL was configured due to comparing int with str returned by logging.getLevelName(). Custom integer log levels crashed with ValueError when logging.getLevelName(int) returned "Level <int>" which failed stdlib setLevel(). Normalize string level names case-insensitively, preserve integer levels, and compare numeric logging levels. Add regression test matrix. Closes #8823 * fix(logger): preserve empty level fallback --------- Co-authored-by: Leandro Damascena <lcdama@amazon.pt>
1 parent ba73859 commit 8a21c19

2 files changed

Lines changed: 125 additions & 13 deletions

File tree

‎aws_lambda_powertools/logging/logger.py‎

Lines changed: 43 additions & 13 deletions
Original file line numberDiff line numberDiff line change
@@ -999,9 +999,34 @@ def _get_aws_lambda_log_level(self) -> str | None:
999999

10001000
return constants.LAMBDA_ADVANCED_LOGGING_LEVELS.get(os.getenv(constants.LAMBDA_LOG_LEVEL_ENV))
10011001

1002-
def _get_powertools_log_level(self, level: str | int | None) -> str | None:
1002+
def _to_numeric_log_level(self, level: str | int) -> int:
1003+
"""Convert a log level name or integer to its numeric value."""
1004+
if isinstance(level, str):
1005+
name = level.upper()
1006+
mapping = (
1007+
logging.getLevelNamesMapping() if hasattr(logging, "getLevelNamesMapping") else logging._nameToLevel
1008+
)
1009+
if name in mapping:
1010+
return mapping[name]
1011+
1012+
val = logging.getLevelName(name)
1013+
if isinstance(val, int):
1014+
return val
1015+
1016+
if hasattr(logging, "_checkLevel"):
1017+
return logging._checkLevel(name)
1018+
1019+
raise ValueError(f"Unknown level: {level!r}")
1020+
1021+
if isinstance(level, int) and not isinstance(level, bool):
1022+
return level
1023+
1024+
raise TypeError(f"Level not an integer or a valid string: {level!r}")
1025+
1026+
def _get_powertools_log_level(self, level: str | int | None) -> str | int | None:
10031027
"""Retrieve the log level for Powertools from the environment variable or level parameter.
1004-
If log level is an integer, we convert to its respective string level `logging.getLevelName()`.
1028+
If log level is an integer, we return it directly as an integer.
1029+
If log level is a string, we normalize it to uppercase.
10051030
If no log level is provided, we check env vars for the log level: POWERTOOLS_LOG_LEVEL_ENV and POWERTOOLS_LOG_LEVEL_LEGACY_ENV.
10061031
Parameters:
10071032
-----------
@@ -1015,19 +1040,24 @@ def _get_powertools_log_level(self, level: str | int | None) -> str | None:
10151040
log level (e.g: INFO, DEBUG, WARNING, ERROR, CRITICAL)
10161041
Returns:
10171042
--------
1018-
str | None:
1043+
str | int | None:
10191044
The corresponding logging level. Returns None if the log level is not explicitly specified.
10201045
""" # noqa E501
10211046

10221047
# Extract log level from Powertools Logger env vars
10231048
log_level_env = os.getenv(constants.POWERTOOLS_LOG_LEVEL_ENV) or os.getenv(
10241049
constants.POWERTOOLS_LOG_LEVEL_LEGACY_ENV,
10251050
)
1026-
# If level is an int (logging.INFO), return its respective string ("INFO")
1027-
if isinstance(level, int):
1028-
return logging.getLevelName(level)
1051+
if isinstance(level, str) and level:
1052+
return level.upper()
1053+
1054+
if isinstance(level, int) and not isinstance(level, bool):
1055+
return level
10291056

1030-
return level or log_level_env
1057+
if log_level_env is not None:
1058+
return log_level_env.upper()
1059+
1060+
return None
10311061

10321062
def _determine_log_level(self, level: str | int | None) -> str | int:
10331063
"""Determine the effective log level considering Lambda and Powertools preferences.
@@ -1038,7 +1068,7 @@ def _determine_log_level(self, level: str | int | None) -> str | int:
10381068
The specified log level as a string, integer, or None.
10391069
Returns:
10401070
----------
1041-
str | int: The effective logging level.
1071+
str | int: The effective logging level.
10421072
"""
10431073

10441074
# This function consider the following order of precedence:
@@ -1051,9 +1081,9 @@ def _determine_log_level(self, level: str | int | None) -> str | int:
10511081
lambda_log_level = self._get_aws_lambda_log_level()
10521082
powertools_log_level = self._get_powertools_log_level(level)
10531083

1054-
if powertools_log_level and lambda_log_level:
1084+
if powertools_log_level is not None and lambda_log_level:
10551085
# If Powertools log level is set and higher than AWS Lambda Advanced Logging Controls, emit a warning
1056-
if logging.getLevelName(lambda_log_level) > logging.getLevelName(powertools_log_level):
1086+
if self._to_numeric_log_level(lambda_log_level) > self._to_numeric_log_level(powertools_log_level):
10571087
warnings.warn(
10581088
f"Current log level ({powertools_log_level}) does not match AWS Lambda Advanced Logging Controls "
10591089
f"minimum log level ({lambda_log_level}). This can lead to data loss, consider adjusting them.",
@@ -1065,8 +1095,8 @@ def _determine_log_level(self, level: str | int | None) -> str | int:
10651095
if (
10661096
hasattr(self, "_buffer_config")
10671097
and self._buffer_config
1068-
and logging.getLevelName(lambda_log_level)
1069-
> logging.getLevelName(self._buffer_config.buffer_at_verbosity)
1098+
and self._to_numeric_log_level(lambda_log_level)
1099+
> self._to_numeric_log_level(self._buffer_config.buffer_at_verbosity)
10701100
):
10711101
warnings.warn(
10721102
"Advanced Logging Controls (ALC) Log Level is less verbose than Log Buffering Log Level. "
@@ -1085,7 +1115,7 @@ def _determine_log_level(self, level: str | int | None) -> str | int:
10851115
return logging.INFO
10861116

10871117
# Powertools log level is set, we use this
1088-
return powertools_log_level.upper()
1118+
return powertools_log_level
10891119

10901120
# FUNCTIONS for Buffering log
10911121

‎tests/functional/logger/required_dependencies/test_logger.py‎

Lines changed: 82 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -1313,6 +1313,88 @@ def test_log_level_advanced_logging_controler_warning_different_log_levels_using
13131313
assert logger.log_level == logging.INFO
13141314

13151315

1316+
@pytest.mark.parametrize(
1317+
"level_input, expected_level",
1318+
[
1319+
("debug", logging.DEBUG),
1320+
("info", logging.INFO),
1321+
("warning", logging.WARNING),
1322+
("error", logging.ERROR),
1323+
("critical", logging.CRITICAL),
1324+
(15, 15),
1325+
(logging.INFO, logging.INFO),
1326+
("", logging.INFO),
1327+
],
1328+
)
1329+
def test_logger_level_case_insensitive_and_integer_without_alc(stdout, service_name, level_input, expected_level):
1330+
# GIVEN no ALC environment variable
1331+
# WHEN Logger is initialized with lowercase string or integer level
1332+
logger = Logger(service=service_name, stream=stdout, level=level_input)
1333+
1334+
# THEN the log level matches the expected numeric level
1335+
assert logger.log_level == expected_level
1336+
1337+
# AND setLevel also accepts lowercase and custom integer
1338+
logger.setLevel(level=level_input)
1339+
assert logger.log_level == expected_level
1340+
1341+
1342+
@pytest.mark.parametrize(
1343+
"level_input, alc_level, should_warn, expected_effective_level",
1344+
[
1345+
("debug", "INFO", True, logging.INFO),
1346+
("info", "INFO", False, logging.INFO),
1347+
("warning", "INFO", False, logging.INFO),
1348+
(15, "INFO", True, logging.INFO),
1349+
(15, "DEBUG", False, logging.DEBUG),
1350+
(25, "INFO", False, logging.INFO),
1351+
],
1352+
)
1353+
def test_logger_level_case_insensitive_and_integer_with_alc(
1354+
monkeypatch,
1355+
stdout,
1356+
service_name,
1357+
level_input,
1358+
alc_level,
1359+
should_warn,
1360+
expected_effective_level,
1361+
):
1362+
# GIVEN ALC is configured
1363+
monkeypatch.setenv(constants.LAMBDA_LOG_LEVEL_ENV, alc_level)
1364+
1365+
# WHEN Logger is initialized with lowercase string or integer level
1366+
if should_warn:
1367+
with pytest.warns(UserWarning):
1368+
logger = Logger(service=service_name, stream=stdout, level=level_input)
1369+
else:
1370+
logger = Logger(service=service_name, stream=stdout, level=level_input)
1371+
1372+
# THEN ALC takes precedence
1373+
assert logger.log_level == expected_effective_level
1374+
1375+
1376+
@pytest.mark.parametrize("env_var", [constants.POWERTOOLS_LOG_LEVEL_ENV, constants.POWERTOOLS_LOG_LEVEL_LEGACY_ENV])
1377+
@pytest.mark.parametrize(
1378+
"env_value, expected_level",
1379+
[
1380+
("debug", logging.DEBUG),
1381+
("info", logging.INFO),
1382+
("warning", logging.WARNING),
1383+
("error", logging.ERROR),
1384+
("critical", logging.CRITICAL),
1385+
],
1386+
)
1387+
def test_logger_env_var_case_insensitive(monkeypatch, stdout, service_name, env_var, env_value, expected_level):
1388+
# GIVEN POWERTOOLS_LOG_LEVEL or LOG_LEVEL is set with lowercase string
1389+
monkeypatch.setenv(env_var, env_value)
1390+
1391+
# WHEN Logger is initialized without explicit level
1392+
logger = Logger(service=service_name, stream=stdout)
1393+
1394+
# THEN Logger normalizes the level case-insensitively
1395+
assert logger.log_level == expected_level
1396+
1397+
13161398
def test_logger_add_remove_filter(stdout, service_name):
13171399
# GIVEN a Logger with a custom logging filter
13181400
class ApiKeyFilter(logging.Filter): # NOSONAR # need filter to test actual impl.

0 commit comments

Comments
 (0)