diff --git a/Modelica/Electrical/PowerConverters/DCAC/Control/SVPWM.mo b/Modelica/Electrical/PowerConverters/DCAC/Control/SVPWM.mo index f13c697af2..e9ff9b3d9c 100644 --- a/Modelica/Electrical/PowerConverters/DCAC/Control/SVPWM.mo +++ b/Modelica/Electrical/PowerConverters/DCAC/Control/SVPWM.mo @@ -22,12 +22,19 @@ block SVPWM "Space vector pulse width modulation" annotation (Placement(transformation(extent={{100,-70},{120,-50}}))); protected discrete Real uRef(start=0, fixed=true) "Length of reference vector"; - discrete SI.Angle phiRef(start=0, fixed=true) "Angle of reference vector within (-pi, +pi]"; - discrete SI.Angle phiPos(start=0, fixed=true) "Angle of reference vector within [0, 2*pi)"; + discrete SI.Angle phiRef(start=0, fixed=true) + "Angle of reference vector within (-pi, +pi]"; + discrete SI.Angle phiPos(start=0, fixed=true) + "Angle of reference vector within [0, 2*pi)"; Integer ka(start=0, fixed=true), kb(start=0, fixed=true) "Switching patterns limiting the sector"; - discrete SI.Angle phiSec(start=0, fixed=true) "Angle of reference vector within sector within [0, pi/m)"; + discrete SI.Angle phiSec(start=0, fixed=true) + "Angle of reference vector within sector within [0, pi/m)"; discrete Real ta(start=0, fixed=true), tb(start=0, fixed=true), t0(start=1, fixed=true) "Relative time spans of vectors a, b, and 0"; - discrete SI.Time T0(start=startTime, fixed=true) "Start time of switching interval"; + // take sector number into account: swapping for sectors 2,4,6 + Integer k1(start=0, fixed=true), k2(start=0, fixed=true) "Switching patterns limiting the sector"; + discrete Real t1(start=0, fixed=true), t2(start=0, fixed=true) "Relative time spans of first and second active vector"; + discrete SI.Time T0(start=startTime, fixed=true) + "Start time of switching interval"; algorithm when sampleTrigger then //Limited relative reference signal @@ -49,25 +56,39 @@ algorithm tb:=min(uRef*sin(phiSec)/sin(pi/m), 1); ta:=min(uRef*cos(phiSec) - tb*cos(pi/m), 1); t0:=max(1 - ta - tb, 0); + // take sector number into account: swapping for sectors 2,4,6 + if mod(ka, 2) == 0 then + // sectors 1,3,5 + k1:=ka; + k2:=kb; + t1:=ta; + t2:=tb; + else + // sectors 2,4,6 + k1:=kb; + k2:=ka; + t1:=tb; + t2:=ta; + end if; //Remember start time of switching interval T0:=time; end when; equation - //Distribute switching patterns t0/4 + ta/2 + tb/2 + t0/2 + tb/2 + ta/2 + t0/4 + //Distribute switching patterns t0/4 + t1/2 + t2/2 + t0/2 + t2/2 + t1/2 + t0/4 if timeta + tb + t0 = 1

+For sectors 2,4,6 ta and tb as well as the vector indices ka and kb have to get swapped. +The results are t1 and t2 as well as k1 and k2, swapped for sector 2,4,6 and without swapping for sector 1,3,5. +

+

To obtain the positive fire signal, the switching time spans are distributed symmetrically: -t0/4 + ta/2 + tb/2 +t0/2 + tb/2 + ta/2 + t0/4 +t0/4 + t1/2 + t2/2 +t0/2 + t2/2 + t1/2 + t0/4

The switching pattern of the negative fire signal is just the inverse of the positive fire signal. diff --git a/Modelica/Electrical/PowerConverters/UsersGuide/References.mo b/Modelica/Electrical/PowerConverters/UsersGuide/References.mo index f45874a96e..cf5a7627b2 100644 --- a/Modelica/Electrical/PowerConverters/UsersGuide/References.mo +++ b/Modelica/Electrical/PowerConverters/UsersGuide/References.mo @@ -25,6 +25,13 @@ class References "References" Principles and Elements of Power Electronics: Devices, Drivers, Applications, and Passive Components, available at University of Strathclyde, ISBN 978-0-9553384-0-3 + + + [TIspra524] + Zhenyu Yu, + +TI Application Report SPRA524: Space-Vector PWM With TMS320C24x/F24x Using Hardware and Software Determined Switching Patterns + ")); end References;